1.
Angiología ; 65(3): 87-90, mayo-jun. 2013. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-112864

RESUMO

El eco-Doppler color (ED) se ha empleado en el diagnóstico de la arteritis de la temporal (AT), describiendo un halo hipoecoico perivascular (HHP). El objetivo de este estudio es valorar la utilidad del ED en el diagnóstico de AT. Material y método: Estudio prospectivo en 32 pacientes con sospecha de AT. Se realizó ED evaluando la presencia de HHP. Posteriormente se practicó biopsia de arteria temporal, analizando la presencia de células gigantes multinucleadas. Se compararon los resultados obtenidos, valorando sensibilidad, especificidad, valor predictivo positivo (VPP) y valor predictivo negativo (VPN).Resultados: La presentación clínica fue: 40,6% (13) cefalea, 12,5% (4) clínica visual, 21,9%(7) dolor de la arteria temporal, 9,4% (3) AIT, 15,6% (5) polimialgia, 9,4% (3) claudicación mandibular, y 87,5% (28) elevación de VSG. Se visualizó HHP en el ED en 6 casos (18,8%). El resultado anatomopatológico de AT fue positivo en 3 casos (9,4%). Al comparar los resultados se obtiene una sensibilidad, especificidad, VPP y VPN del 66, 86, 33 y 96%, respectivamente. Conclusión: El ED es una prueba útil en el diagnóstico de AT, dejando la biopsia de la arteria temporal para casos seleccionados (AU)


Duplex ultrasound (DU) has been used in the diagnosis of temporal arteritis (TA), showing a hypoechoic perivascular halo (HPH). The aim of this study is to assess the usefulness of DU in the diagnosis of TA. Materials and method: A prospective study was conducted on 32 patients with suspected TA. DU was performed to detect the presence of HPH. A temporal artery biopsy was subsequently to analyse the presence of multinucleated giant cells. The results were compared by evaluating sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The clinical presentation was: 40.6% (13) headache, 12.5% (4) visual clinical signs,21.9% (7) temporal artery pain, 9.4% (3) TIA, 15.6% (5) polymyalgia, 9.4% (3) jaw claudication, and 87.5% (28) elevated ESR.HPH was visualized in the DU in 6 cases (18.8%). The pathology of TA was positive in 3 patients (9.4%). On analysing the results, the sensitivity, specificity, PPV and NPV was 66%, 86%, 33%, and 96%, respectively. Conclusion: DU is a useful screening test in diagnosis of TA, leaving temporal artery biopsy for selected cases (AU)


Assuntos
Humanos , Artérias Temporais/patologia , Arterite de Células Gigantes/patologia , Biópsia , Ultrassonografia Doppler/métodos , Estudos Prospectivos , Seleção de Pacientes
2.
Angiología ; 64(5): 193-198, sept.-oct. 2012. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-102625

RESUMO

Objetivos: Validar el eco-Doppler portátil (EDP) para el diagnóstico de enfermedad arterial periférica (EAP) y analizar la influencia del tipo de lesión arterial en el resultado. Material y método: Estudio prospectivo: 60 extremidades (45 pacientes), edad media 68 años, 33 hombres/12 mujeres, 30% diabéticos, 37% dislipémicos, 58% hipertensos, 27% cardiópatas. Realizamos un EDP siguiendo las guías de diagnóstico vascular no invasivo del sector femoropoplíteo (8 segmentos), comparándolo con la arteriografía. Clasificamos como estenosis < 50%, > 50% y trombosis. Calculamos sensibilidad (S), especificidad (E), VPP, VPN e índice de acuerdo kappa. Las lesiones arteriales se clasifican en únicas o múltiples y se comparan con el grado de acierto del EDP (test chi cuadrado). Resultados: En el sector supragenicular el índice de acuerdo es bueno para diagnóstico de trombosis (K=0,779, S=86%, E=95%, VPP=79%, VPN=96%) y de estenosis > 50% (K=0,651, S=82%, E=85%, VPP=70% y VPN=92%).En el sector infragenicular el grado de acuerdo es bueno para diagnóstico de trombosis (K=0,610, S=72%, E=87%, VPP=77%, VPN 84%), pero moderado en estenosis > 50% (K=0,472, S=68%, E=78%, VPP=70% y VPN=76%).El EDP identifica correctamente 94% de trombosis en lesiones únicas frente 85% en estenosis múltiples (p=0,008) y 86% de estenosis > 50% en lesiones únicas frente 79% en múltiples (p=0,070). Conclusiones: La sensibilidad, especificidad, VPP y VPN del EDP son buenos en diagnóstico de EAP siendo más sensible para diagnóstico de trombosis que estenosis.- El EDP ofrece mayor fiabilidad en diagnóstico de EAP en sector supragenicular frente al infragenicular.- Las lesiones arteriales múltiples disminuyen la fiabilidad del EDP en el diagnóstico de trombosis(AU)


Objectives: The aim of this study is investigate the agreement between a portable duplex scanner (PDS and angiography in the diagnosis of peripheral arterial disease (PAD) and analyse the influence of the type of lesion on the result. Material and methods: A prospective study was conducted on 60 limbs (45 patients) with a mean age of 68 years, 33 males/12 females, 30% diabetes mellitus, 37% dyslipidaemias, 58% arterial hypertension, and 27% heart diseases. A PDS was made following the guidelines for the non-invasive diagnosis of femoral-popliteal sector (8 segments) and comparing it with the angiography. The stenosis were classified as <50%, and thrombosis as >50%. The sensitivity (Se), specificity (Sp), Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Kappa (K) index of agreement was calculated. The arterial lesions were classified in singles or multiples, and were compared with the level of accuracy of the PDS (chi-squared test). Results: In the above-knee segment, the level of agreement was good for the diagnosis of thrombosis (K=0.779, Sp=86%, Se=95%, PPV=79%, NPV=96%) and stenosis >50% (K=0.651, Se=82%, Se=85%, PPV=70% and NPV=92%).In the below-knee segment, the index of agreement was good for the diagnosis of thrombosis (K=0.610, Sp=72%, Se=87%, PPV=77%, PNV=84%), and moderate in stenosis >50% (K=0.472, Sp=68%, Se=78%, PPV=70% and NPV=76%).The PDS correctly identified 94% of thrombosis in single lesions compared to 85% in the multiple lesions (P=.008) and 86% in stenosis >50% in single lesions compared to 79% in multiple lesions (P=.070)(AU)


Conclusions: The sensitivity, specificity, PPV, NPV and Kappa index are good in the diagnosis of PAD, being more sensitive for the diagnosis of thrombosis than for the diagnosis of stenosis.- The was more reliable for the diagnosis of PAD in above-knee segments than below-knee segments.- Multiple arterial lesions decrease the reliability of PDS in the diagnosis of thrombosis(AU)


Assuntos
Humanos , Doença Arterial Periférica , Ultrassonografia Doppler/métodos , Angiografia , Sensibilidade e Especificidade
3.
Angiología ; 59(1): 29-37, ene.-feb. 2007. ilus, tab
Artigo em Es | IBECS | ID: ibc-051920

RESUMO

Introducción. El control clínico del tratamiento endovascular de la enfermedad aneurismática de la aorta abdominal se basa en la valoración de la evolución del tamaño del aneurisma, la permeabilidad de la endoprótesis y la detección de fugas. Objetivo. Comparar la ecografía Doppler (ED) color con la tomografía axial computarizada (TAC) en la evaluación del tamaño del aneurisma y la detección de fugas en el tratamiento endovascular de aneurismas de aorta abdominal. Pacientes y métodos. Estudio prospectivo entre enero y diciembre de 2005. En 14 pacientes sometidos a tratamiento endovascular se realizó ED color y TAC a 1, 6 y 12 meses. Se compararon los tamaños del aneurisma mediante la prueba t para muestras dependientes y estudio de correlación. Sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo y el coeficiente de concordancia kappa se calcularon para la detección de fugas. Resultados. El control clínico medio fue de 9,4 meses y se compararon 49 exploraciones. El diámetro medio del aneurisma a los tres meses de control clínico fue de 51,2 cm con ED color y de 52,5 cm con TAC (p = no significativo). El coeficiente de correlación ascendió a 0,97 (p < 0,001). Todos los dispositivos se mantuvieron permeables. En detección de fugas, el estudio ED color obtuvo una sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo de 75, 61, 20 y 95%, respectivamente (kappa = 0,61). Conclusiones. El estudio ED color obtiene una excelente correlación con la TAC en la medida del tamaño de los aneurismas. En cambio, posee un valor predictivo positivo muy bajo para la detección de fugas


Introduction. Clinical monitoring of the endovascular treatment of aneurysmal disease of the abdominal aorta is based on evaluating the progression of the size of the aneurysm, the patency of the stent and the detection of leaks. Aim. To compare colour Doppler ultrasonography (DU) with computerised axial tomography (CAT) for evaluating the size of the aneurysm and the detection of leaks in the endovascular treatment of abdominal aortic aneurysms. Patients and methods. A prospective study between January and December 2005; colour DU and CAT scans were conducted in 14 patients submitted to endovascular treatment at 1, 6 and 12 months. Sizes of the aneurysms were compared by means of the t test for dependent samples and correlation studies. Sensitivity, specificity, predictive positive value and predictive negative value and the kappa coefficient of agreement were calculated for leak detection. Results. The mean period of clinical monitoring was 9.4 months and 49 examinations were compared. The mean diameter of the aneurysm at three months’ clinical monitoring was 51.2 cm with colour DU and 52.5 cm with CAT scanning (p = non-significant). The correlation coefficient was 0.97 (p < 0.001). Patency was maintained in all the devices. In the detection of leaks, the results of the colour DU study for sensitivity, specificity, predictive positive value and predictive negative value were 75, 61, 20 and 95%, respectively (kappa = 0.61). Conclusions. The colour DU study correlates very well with CAT in the measurement of the size of aneurysms. In contrast, it has a very low predictive positive value for the detection of leaks


Assuntos
Humanos , Aneurisma da Aorta Abdominal/cirurgia , Ecocardiografia Doppler em Cores , Tomografia Computadorizada por Raios X , Aneurisma da Aorta Abdominal , Aneurisma da Aorta Abdominal , Reprodutibilidade dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Seguimentos , Valor Preditivo dos Testes
4.
Angiología ; 58(3): 223-230, mayo-jun. 2006. ilus, tab
Artigo em Es | IBECS | ID: ibc-046265

RESUMO

Objetivo. Comparar la precisión diagnóstica de varios parámetros hemodinámicos en la graduación de la estenosis carotídea en pacientes con oclusión contralateral. Pacientes y métodos. Se diseñó un estudio prospectivo de 76 pacientes con oclusión carotídea unilateral, en el que se correlacionaron de manera ciega los hallazgos de eco- Doppler color y arteriografía. Cada carótida se clasificó, según el grado estenótico angiográfico, en: 1-29% (n = 39), 30-49% (n = 15), 50-69% (n = 14), >= 70% (n = 8). Se consideraron cinco criterios hemodinámicos para valorar una estenosis > 50%: Universidad de Washington (estándar); AbuRahma (pico de velocidad sistólica, PSV > 140 cm/s; velocidad diastólica final, EDV 140 cm/s; EDV 1,5; y método nuevo (ratio de la ICA/CCA > 1,3; PSV > 115 cm/s). Se calcularon la sensibilidad, la especificidad, los valores predictivos positivo y negativo, el valor diagnóstico y el índice de concordancia κ. Resultados. La mejor concordancia arteriografía/eco-Doppler se dio para el método nuevo (κ = 0,59), con una precisión diagnóstica del 84,2, seguida del método estándar (que obtuvo una κ = 0,53 y una precisión de 82,8). Los métodos específicos para pacientes con trombosis carotídea unilateral (AbuRahma y Fujitani) fueron los menos eficaces, mientras que el método de la ratio presentó resultados intermedios. Conclusiones. La presencia de oclusión produce una sobreestimación o infraestimación del grado estenótico ipsilateral según los criterios clásicos admitidos. Este problema puede reducirse mediante la utilización de una ratio > 1,3 y un PSV > 115 cm/s. Para evaluar el grado de progresión de la enfermedad carotídea cada laboratorio ha de validar sus propios criterios, los cuales deben permitir diferenciar entre lesiones hemodinámicamente significativas y aquellas que no lo son (AU)


Aim. To compare the accuracy of various duplex hemodynamic criteria in grading ipsilateral carotid stenosis in patients with contralateral occlusion. Patients and methods. A prospective study was designed with 76 patients who had unilateral carotid occlusion, the results of duplex were correlated in blind fashion to arteriography. Each carotid was classified in order to the angiographic stenotic grade in: 1-29% (n = 39), 30-49% (n = 15), 50-69% (n = 14), ≥ 70% (n = 8). Five duplex ultrasonography classification criteria for discriminate > 50% stenosis were used: Washington University (standard), AbuRahma (peak systolic velocity, PSV > 140 cm/s; diastolic velocity, EDV 140 cm/s; EDV 1.5; new method (ratio ICA/ CCA > 1.3; PSV > 115 cm/s). The sensibility, specificity, positive predictive value, negative predictive value, accuracy and κ index were calculated. Results. Best concordance between angiography and duplex was for the new method, providing a κ = 0.59 and an accuracy of 84.2, followed by standard method that obtained κ = 0.53 and an accuracy of 82.8. Specific methods for patients with unilateral occlusion of ICA (AbuRahma and Fujitani) provided inferior efficacy in detecting carotid stenosis >= 50%, although the ratio method obtained intermediate results. Conclusions. The fact of having a contralateral occlusion of the ICA produces some overestimation or underestimation of the ipsilatral carotid stenosis degree following the classic criteria. This problem can be reduced using a ratio > 1.3 and a PSV > 115 cm/s. Each laboratory should perform an objective evaluation of their own criteria of diagnosis to discriminate hemodynamically significant lesions (AU)


Assuntos
Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Humanos , Trombose das Artérias Carótidas/complicações , Trombose das Artérias Carótidas/diagnóstico , Trombose das Artérias Carótidas/terapia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Ultrassonografia Doppler em Cores/métodos , Angiografia/métodos , Sensibilidade e Especificidade , Valor Preditivo dos Testes , Estudos Prospectivos , Ecocardiografia Doppler/métodos , Doenças das Artérias Carótidas , Estenose das Carótidas
5.
Angiología ; 53(5): 321-327, sept. 2001. ilus
Artigo em Es | IBECS | ID: ibc-10003

RESUMO

Describimos una técnica de reconstrucción de la arteria vertebral en su segmento proximal. Realizamos transposición de la arteria vertebral al tronco tirocervical; tras ligar sus ramas, aprovechamos el muñón para realizar la anastomosis. Pacientes y métodos. Revisamos retrospectivamente nuestra experiencia, desde 1992 hasta 2001. Realizamos dicha reconstrucción a cinco pacientes varones, con sintomatología vertebrobasilar, con edad media 64 años y patología en carótida común o interna ipsilateral o carótida interna contralateral. Técnica quirúrgica: en un primer tiempo se llevó a cabo la intervención sobre la carótida interna contralateral (n= 3). Al mes, realizamos un abordaje medial al esternocleidomastoideo, mediante incisión oblicua supraclavicular; al disecar entre carótida común y yugular interna vemos nervio vago, conducto torácico y vena vertebral que ligamos, observando la arteria vertebral. Seccionamos la arteria vertebral por debajo de la lesión. Hemos de tener sumo cuidado con la cadena simpática cervical, nervio vertebral y ganglio simpático cervical inferior. Lateralmente al origen de la vertebral nace el tronco tirocervical, ligamos sus ramas y sobre el muñón realizamos la anastomosis de la arteria vertebral mediante pinzamiento subclavio parcial. Resultados. Se realizaron cinco transposiciones, un paciente sufrió un accidente isquémico transitorio en el postoperatorio inmediato, con recuperación sin secuelas. Durante el seguimiento se observó, mediante ecografía Doppler, permeabilidad del 100 por ciento, y sólo un paciente falleció al tercer año por cardiopatía isquémica. Conclusión. Creemos que la transposición del segmento proximal de la arteria vertebral al tronco tirocervical es una maniobra quirúrgica poco agresiva, sin pinzamientos de troncos principales, que acorta el acto quirúrgico y tiene baja morbimortalidad (AU)


Assuntos
Masculino , Pessoa de Meia-Idade , Humanos , Artéria Vertebral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Doenças das Artérias Carótidas/cirurgia , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Seguimentos , Soroglobulinas , Permeabilidade Capilar , Angiografia
6.
Cir Pediatr ; 3(4): 145-8, 1990 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-2076359

RESUMO

With the aim of detecting possible interferences in the absorption of glucose, amino acids and fats we infused several combination of them into the peritoneal cavity of the Wistar rats. After intraperitoneal infusion of 2 mu Ci-L-glucose-C14 with 5 ml of D-glucose 5 per 100 and L-glucose-C14 with 5 ml of "16N" 3.5 per 100 in different groups of animals, we detected slight differences in plasma radioactivity one hour after infusion. We also found moderated differences in plasma radioactivity among the groups of animals infused with 1 mu Ci of fat radioactive amino acids plus 5 ml of D-glucose 5 per 100 and in the group infused with 1 mu Ci of 5-L-amino acid-C14 plus 5 ml of "16N" 3.5 per 100, after four hours of the infusion. We found no differences among those groups of animals infused with fat plus glucose and with fat plus amino acid with respect to those infused with fat alone. In summary, as glucose and amino acid absorption pathway are the same (capillary flow) seem reasonable that they interfere with each other when they are infused intraperitoneally. Fat infusion that not seem to interfere with other substrates possible due to the different absorption pathway (lymphatic channels) but further studies are needed to determine this.


Assuntos
Fenômenos Fisiológicos da Nutrição Animal , Cavidade Peritoneal/fisiologia , Absorção , Aminoácidos/administração & dosagem , Animais , Radioisótopos de Carbono , Interações Medicamentosas , Emulsões Gordurosas Intravenosas/administração & dosagem , Glucose/administração & dosagem , Infusões Parenterais , Ratos